This commit is contained in:
gongxh
2022-01-19 09:31:47 +08:00
parent 89f1bb0536
commit 9cfeb818fa
3 changed files with 56 additions and 37 deletions

View File

@@ -144,8 +144,10 @@ namespace CleanMachineHMI.FrmUserControl
// kcmb_plcAlarmStatus
//
this.kcmb_plcAlarmStatus.Anchor = System.Windows.Forms.AnchorStyles.None;
this.kcmb_plcAlarmStatus.DrawMode = System.Windows.Forms.DrawMode.OwnerDrawVariable;
this.kcmb_plcAlarmStatus.DropDownStyle = System.Windows.Forms.ComboBoxStyle.DropDownList;
this.kcmb_plcAlarmStatus.DropDownWidth = 248;
this.kcmb_plcAlarmStatus.IntegralHeight = false;
this.kcmb_plcAlarmStatus.Items.AddRange(new object[] {
"请选择",
"正在报警",
@@ -167,8 +169,10 @@ namespace CleanMachineHMI.FrmUserControl
// kcmb_plcAlarmHandleResult
//
this.kcmb_plcAlarmHandleResult.Anchor = System.Windows.Forms.AnchorStyles.None;
this.kcmb_plcAlarmHandleResult.DrawMode = System.Windows.Forms.DrawMode.OwnerDrawVariable;
this.kcmb_plcAlarmHandleResult.DropDownStyle = System.Windows.Forms.ComboBoxStyle.DropDownList;
this.kcmb_plcAlarmHandleResult.DropDownWidth = 248;
this.kcmb_plcAlarmHandleResult.IntegralHeight = false;
this.kcmb_plcAlarmHandleResult.Items.AddRange(new object[] {
"请选择",
"未处理",
@@ -232,6 +236,7 @@ namespace CleanMachineHMI.FrmUserControl
this.kbtn_UuivertorAlarmClear.Size = new System.Drawing.Size(135, 35);
this.kbtn_UuivertorAlarmClear.TabIndex = 2;
this.kbtn_UuivertorAlarmClear.Values.Text = "变频器报警清除";
this.kbtn_UuivertorAlarmClear.Click += new System.EventHandler(this.kbtn_UuivertorAlarmClear_Click);
this.kbtn_UuivertorAlarmClear.MouseDown += new System.Windows.Forms.MouseEventHandler(this.kbtn_UuivertorAlarmClear_MouseDown);
this.kbtn_UuivertorAlarmClear.MouseUp += new System.Windows.Forms.MouseEventHandler(this.kbtn_UuivertorAlarmClear_MouseUp);
//

View File

@@ -151,15 +151,17 @@ namespace CleanMachineHMI.FrmUserControl
{
tmpWarningLogList.OrderByDescending(x => x.WarningTime);
DataTable dt = new DataTable();
DataColumn dc1 = new DataColumn("序号", Type.GetType("System.Int32"));
DataColumn dc2 = new DataColumn("PLC变量地址", Type.GetType("System.String"));
DataColumn dc3 = new DataColumn("报警条码", Type.GetType("System.String"));
DataColumn dc4 = new DataColumn("报警内容", Type.GetType("System.String"));
DataColumn dc5 = new DataColumn("报警时间", Type.GetType("System.String"));
DataColumn dc6 = new DataColumn("报警状态", Type.GetType("System.String"));
DataColumn dc7 = new DataColumn("处理结果", Type.GetType("System.String"));
DataColumn dc8 = new DataColumn("处理时间", Type.GetType("System.String"));
DataColumn dc9 = new DataColumn("报警时长", Type.GetType("System.String"));
DataColumn dc1 = new DataColumn("序号", typeof(int));
DataColumn dc2 = new DataColumn("PLC变量地址", typeof(string));
DataColumn dc3 = new DataColumn("报警条码", typeof(string));
DataColumn dc4 = new DataColumn("报警内容", typeof(string));
DataColumn dc5 = new DataColumn("报警时间", typeof(string));
DataColumn dc6 = new DataColumn("报警状态", typeof(string));
DataColumn dc7 = new DataColumn("处理结果", typeof(string));
DataColumn dc8 = new DataColumn("处理时间", typeof(string));
DataColumn dc9 = new DataColumn("报警时长", typeof(string));
dt.Columns.Add(dc1);
dt.Columns.Add(dc2);
@@ -269,5 +271,10 @@ namespace CleanMachineHMI.FrmUserControl
KryptonMessageBox.Show(ex.Message);
}
}
private void kbtn_UuivertorAlarmClear_Click(object sender, EventArgs e)
{
}
}
}

View File

@@ -80,8 +80,11 @@ namespace CleanMachineHMI
/// <returns></returns>
public bool PlcInit()
{
#if !DEBUG
try
{
#endif
string portname = GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'PortName'")[0]["PARAMETER_VALUE"].ToString();
int baudrate = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'BaudRate'")[0]["PARAMETER_VALUE"]);
int databits = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'DataBits'")[0]["PARAMETER_VALUE"]);
@@ -93,8 +96,8 @@ namespace CleanMachineHMI
var adaptet = new NModbus.IO.TcpClientAdapter(port);
#else
var SerialPort=new SerialPort(portname, baudrate, paritymsg, databits, stopbis);
port = new NModbus.Serial.SerialPortAdapter(SerialPort);
port = new SerialPort(portname, baudrate, paritymsg, databits, stopbis);
var adaptet = new NModbus.Serial.SerialPortAdapter(port);
#endif
var factory = new ModbusFactory();
@@ -108,14 +111,15 @@ namespace CleanMachineHMI
master = factory.CreateAsciiMaster(adaptet);
}
#if USE_LOCAL_TCP_DEBUG
port.Connect("127.0.0.1", 5002);
port.Connect("10.0.0.95", 5002);
this._isConn = true;
#else
SerialPort.Open();
port.Open();
#endif
return true;
#if !DEBUG
}
catch (Exception ex)
{
@@ -123,6 +127,7 @@ namespace CleanMachineHMI
isConn = false;
return false;
}
#endif
}
public void ClosePlcConn()
{
@@ -662,6 +667,7 @@ namespace CleanMachineHMI
#endif
}
public object ReadPlcItem(string plcItemCode, PlcItemTypeDesc itemType)
{
#if !DEBUG
@@ -672,6 +678,7 @@ namespace CleanMachineHMI
switch (itemType)
{
case PlcItemTypeDesc.M:
PlcItem item_M = GlobalHelper.PlcItemMd_M_List.Find(x => x.PlcItemCode == plcItemCode);
if (item_M == null)
{