diff --git a/CleanMachineHMI/FrmUserControl/frmPlcAlarmLog.Designer.cs b/CleanMachineHMI/FrmUserControl/frmPlcAlarmLog.Designer.cs index de3cae9..543dd2c 100644 --- a/CleanMachineHMI/FrmUserControl/frmPlcAlarmLog.Designer.cs +++ b/CleanMachineHMI/FrmUserControl/frmPlcAlarmLog.Designer.cs @@ -144,8 +144,10 @@ namespace CleanMachineHMI.FrmUserControl // kcmb_plcAlarmStatus // this.kcmb_plcAlarmStatus.Anchor = System.Windows.Forms.AnchorStyles.None; + this.kcmb_plcAlarmStatus.DrawMode = System.Windows.Forms.DrawMode.OwnerDrawVariable; this.kcmb_plcAlarmStatus.DropDownStyle = System.Windows.Forms.ComboBoxStyle.DropDownList; this.kcmb_plcAlarmStatus.DropDownWidth = 248; + this.kcmb_plcAlarmStatus.IntegralHeight = false; this.kcmb_plcAlarmStatus.Items.AddRange(new object[] { "请选择", "正在报警", @@ -167,8 +169,10 @@ namespace CleanMachineHMI.FrmUserControl // kcmb_plcAlarmHandleResult // this.kcmb_plcAlarmHandleResult.Anchor = System.Windows.Forms.AnchorStyles.None; + this.kcmb_plcAlarmHandleResult.DrawMode = System.Windows.Forms.DrawMode.OwnerDrawVariable; this.kcmb_plcAlarmHandleResult.DropDownStyle = System.Windows.Forms.ComboBoxStyle.DropDownList; this.kcmb_plcAlarmHandleResult.DropDownWidth = 248; + this.kcmb_plcAlarmHandleResult.IntegralHeight = false; this.kcmb_plcAlarmHandleResult.Items.AddRange(new object[] { "请选择", "未处理", @@ -232,6 +236,7 @@ namespace CleanMachineHMI.FrmUserControl this.kbtn_UuivertorAlarmClear.Size = new System.Drawing.Size(135, 35); this.kbtn_UuivertorAlarmClear.TabIndex = 2; this.kbtn_UuivertorAlarmClear.Values.Text = "变频器报警清除"; + this.kbtn_UuivertorAlarmClear.Click += new System.EventHandler(this.kbtn_UuivertorAlarmClear_Click); this.kbtn_UuivertorAlarmClear.MouseDown += new System.Windows.Forms.MouseEventHandler(this.kbtn_UuivertorAlarmClear_MouseDown); this.kbtn_UuivertorAlarmClear.MouseUp += new System.Windows.Forms.MouseEventHandler(this.kbtn_UuivertorAlarmClear_MouseUp); // diff --git a/CleanMachineHMI/FrmUserControl/frmPlcAlarmLog.cs b/CleanMachineHMI/FrmUserControl/frmPlcAlarmLog.cs index 29eceb6..b996224 100644 --- a/CleanMachineHMI/FrmUserControl/frmPlcAlarmLog.cs +++ b/CleanMachineHMI/FrmUserControl/frmPlcAlarmLog.cs @@ -151,15 +151,17 @@ namespace CleanMachineHMI.FrmUserControl { tmpWarningLogList.OrderByDescending(x => x.WarningTime); DataTable dt = new DataTable(); - DataColumn dc1 = new DataColumn("序号", Type.GetType("System.Int32")); - DataColumn dc2 = new DataColumn("PLC变量地址", Type.GetType("System.String")); - DataColumn dc3 = new DataColumn("报警条码", Type.GetType("System.String")); - DataColumn dc4 = new DataColumn("报警内容", Type.GetType("System.String")); - DataColumn dc5 = new DataColumn("报警时间", Type.GetType("System.String")); - DataColumn dc6 = new DataColumn("报警状态", Type.GetType("System.String")); - DataColumn dc7 = new DataColumn("处理结果", Type.GetType("System.String")); - DataColumn dc8 = new DataColumn("处理时间", Type.GetType("System.String")); - DataColumn dc9 = new DataColumn("报警时长", Type.GetType("System.String")); + + + DataColumn dc1 = new DataColumn("序号", typeof(int)); + DataColumn dc2 = new DataColumn("PLC变量地址", typeof(string)); + DataColumn dc3 = new DataColumn("报警条码", typeof(string)); + DataColumn dc4 = new DataColumn("报警内容", typeof(string)); + DataColumn dc5 = new DataColumn("报警时间", typeof(string)); + DataColumn dc6 = new DataColumn("报警状态", typeof(string)); + DataColumn dc7 = new DataColumn("处理结果", typeof(string)); + DataColumn dc8 = new DataColumn("处理时间", typeof(string)); + DataColumn dc9 = new DataColumn("报警时长", typeof(string)); dt.Columns.Add(dc1); dt.Columns.Add(dc2); @@ -269,5 +271,10 @@ namespace CleanMachineHMI.FrmUserControl KryptonMessageBox.Show(ex.Message); } } + + private void kbtn_UuivertorAlarmClear_Click(object sender, EventArgs e) + { + + } } } diff --git a/CleanMachineHMI/Utils/PlcOperationHelper.cs b/CleanMachineHMI/Utils/PlcOperationHelper.cs index 3109bad..2afe91d 100644 --- a/CleanMachineHMI/Utils/PlcOperationHelper.cs +++ b/CleanMachineHMI/Utils/PlcOperationHelper.cs @@ -80,49 +80,54 @@ namespace CleanMachineHMI /// public bool PlcInit() { + +#if !DEBUG try { - string portname = GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'PortName'")[0]["PARAMETER_VALUE"].ToString(); - int baudrate = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'BaudRate'")[0]["PARAMETER_VALUE"]); - int databits = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'DataBits'")[0]["PARAMETER_VALUE"]); - StopBits stopbis = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'StopBits'")[0]["PARAMETER_VALUE"]) == 0 ? StopBits.None : (Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'StopBits'")[0]["PARAMETER_VALUE"]) == 1 ? StopBits.One : StopBits.Two); - Parity paritymsg = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'ParityMsg'")[0]["PARAMETER_VALUE"]) == 0 ? Parity.None : (Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'ParityMsg'")[0]["PARAMETER_VALUE"]) == 1 ? Parity.Odd : Parity.Even); - int modbusPattern = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'ModbusPattern'")[0]["PARAMETER_VALUE"]); +#endif + string portname = GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'PortName'")[0]["PARAMETER_VALUE"].ToString(); + int baudrate = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'BaudRate'")[0]["PARAMETER_VALUE"]); + int databits = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'DataBits'")[0]["PARAMETER_VALUE"]); + StopBits stopbis = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'StopBits'")[0]["PARAMETER_VALUE"]) == 0 ? StopBits.None : (Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'StopBits'")[0]["PARAMETER_VALUE"]) == 1 ? StopBits.One : StopBits.Two); + Parity paritymsg = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'ParityMsg'")[0]["PARAMETER_VALUE"]) == 0 ? Parity.None : (Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'ParityMsg'")[0]["PARAMETER_VALUE"]) == 1 ? Parity.Odd : Parity.Even); + int modbusPattern = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'ModbusPattern'")[0]["PARAMETER_VALUE"]); #if USE_LOCAL_TCP_DEBUG - port = new System.Net.Sockets.TcpClient(); + port = new System.Net.Sockets.TcpClient(); - var adaptet = new NModbus.IO.TcpClientAdapter(port); + var adaptet = new NModbus.IO.TcpClientAdapter(port); #else - var SerialPort=new SerialPort(portname, baudrate, paritymsg, databits, stopbis); - port = new NModbus.Serial.SerialPortAdapter(SerialPort); + port = new SerialPort(portname, baudrate, paritymsg, databits, stopbis); + var adaptet = new NModbus.Serial.SerialPortAdapter(port); #endif - var factory = new ModbusFactory(); - if (modbusPattern == 0) - { + var factory = new ModbusFactory(); + if (modbusPattern == 0) + { - master = factory.CreateRtuMaster(adaptet); - } - else - { - master = factory.CreateAsciiMaster(adaptet); - } -#if USE_LOCAL_TCP_DEBUG - port.Connect("127.0.0.1", 5002); - this._isConn = true; -#else - - SerialPort.Open(); -#endif - - return true; + master = factory.CreateRtuMaster(adaptet); } + else + { + master = factory.CreateAsciiMaster(adaptet); + } +#if USE_LOCAL_TCP_DEBUG + port.Connect("10.0.0.95", 5002); + this._isConn = true; +#else + + port.Open(); +#endif + + return true; +#if !DEBUG + } catch (Exception ex) { LogHelper.WriteLog($"初始化PLC连接时发生异常:【{ex.Message}】", LogTypeEum.Err); isConn = false; return false; } +#endif } public void ClosePlcConn() { @@ -662,6 +667,7 @@ namespace CleanMachineHMI #endif } + public object ReadPlcItem(string plcItemCode, PlcItemTypeDesc itemType) { #if !DEBUG @@ -672,6 +678,7 @@ namespace CleanMachineHMI switch (itemType) { case PlcItemTypeDesc.M: + PlcItem item_M = GlobalHelper.PlcItemMd_M_List.Find(x => x.PlcItemCode == plcItemCode); if (item_M == null) {