This commit is contained in:
gongxh
2022-01-19 09:31:47 +08:00
parent 89f1bb0536
commit 9cfeb818fa
3 changed files with 56 additions and 37 deletions

View File

@@ -80,49 +80,54 @@ namespace CleanMachineHMI
/// <returns></returns>
public bool PlcInit()
{
#if !DEBUG
try
{
string portname = GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'PortName'")[0]["PARAMETER_VALUE"].ToString();
int baudrate = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'BaudRate'")[0]["PARAMETER_VALUE"]);
int databits = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'DataBits'")[0]["PARAMETER_VALUE"]);
StopBits stopbis = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'StopBits'")[0]["PARAMETER_VALUE"]) == 0 ? StopBits.None : (Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'StopBits'")[0]["PARAMETER_VALUE"]) == 1 ? StopBits.One : StopBits.Two);
Parity paritymsg = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'ParityMsg'")[0]["PARAMETER_VALUE"]) == 0 ? Parity.None : (Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'ParityMsg'")[0]["PARAMETER_VALUE"]) == 1 ? Parity.Odd : Parity.Even);
int modbusPattern = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'ModbusPattern'")[0]["PARAMETER_VALUE"]);
#endif
string portname = GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'PortName'")[0]["PARAMETER_VALUE"].ToString();
int baudrate = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'BaudRate'")[0]["PARAMETER_VALUE"]);
int databits = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'DataBits'")[0]["PARAMETER_VALUE"]);
StopBits stopbis = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'StopBits'")[0]["PARAMETER_VALUE"]) == 0 ? StopBits.None : (Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'StopBits'")[0]["PARAMETER_VALUE"]) == 1 ? StopBits.One : StopBits.Two);
Parity paritymsg = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'ParityMsg'")[0]["PARAMETER_VALUE"]) == 0 ? Parity.None : (Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'ParityMsg'")[0]["PARAMETER_VALUE"]) == 1 ? Parity.Odd : Parity.Even);
int modbusPattern = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'ModbusPattern'")[0]["PARAMETER_VALUE"]);
#if USE_LOCAL_TCP_DEBUG
port = new System.Net.Sockets.TcpClient();
port = new System.Net.Sockets.TcpClient();
var adaptet = new NModbus.IO.TcpClientAdapter(port);
var adaptet = new NModbus.IO.TcpClientAdapter(port);
#else
var SerialPort=new SerialPort(portname, baudrate, paritymsg, databits, stopbis);
port = new NModbus.Serial.SerialPortAdapter(SerialPort);
port = new SerialPort(portname, baudrate, paritymsg, databits, stopbis);
var adaptet = new NModbus.Serial.SerialPortAdapter(port);
#endif
var factory = new ModbusFactory();
if (modbusPattern == 0)
{
var factory = new ModbusFactory();
if (modbusPattern == 0)
{
master = factory.CreateRtuMaster(adaptet);
}
else
{
master = factory.CreateAsciiMaster(adaptet);
}
#if USE_LOCAL_TCP_DEBUG
port.Connect("127.0.0.1", 5002);
this._isConn = true;
#else
SerialPort.Open();
#endif
return true;
master = factory.CreateRtuMaster(adaptet);
}
else
{
master = factory.CreateAsciiMaster(adaptet);
}
#if USE_LOCAL_TCP_DEBUG
port.Connect("10.0.0.95", 5002);
this._isConn = true;
#else
port.Open();
#endif
return true;
#if !DEBUG
}
catch (Exception ex)
{
LogHelper.WriteLog($"初始化PLC连接时发生异常:【{ex.Message}】", LogTypeEum.Err);
isConn = false;
return false;
}
#endif
}
public void ClosePlcConn()
{
@@ -662,6 +667,7 @@ namespace CleanMachineHMI
#endif
}
public object ReadPlcItem(string plcItemCode, PlcItemTypeDesc itemType)
{
#if !DEBUG
@@ -672,6 +678,7 @@ namespace CleanMachineHMI
switch (itemType)
{
case PlcItemTypeDesc.M:
PlcItem item_M = GlobalHelper.PlcItemMd_M_List.Find(x => x.PlcItemCode == plcItemCode);
if (item_M == null)
{