修改
This commit is contained in:
@@ -7,7 +7,7 @@
|
||||
//启用心跳检查
|
||||
|
||||
#if RELEASE
|
||||
#define UseHeartbeat
|
||||
#define UseHeartbeat
|
||||
#endif
|
||||
using CleanMachine.Model;
|
||||
using LeadDataBaseUtility;
|
||||
@@ -90,45 +90,58 @@ namespace CleanMachineHMI
|
||||
public bool PlcInit()
|
||||
{
|
||||
|
||||
#if RELEASE
|
||||
|
||||
try
|
||||
{
|
||||
#endif
|
||||
string portname = GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'PortName'")[0]["PARAMETER_VALUE"].ToString();
|
||||
int baudrate = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'BaudRate'")[0]["PARAMETER_VALUE"]);
|
||||
int databits = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'DataBits'")[0]["PARAMETER_VALUE"]);
|
||||
StopBits stopbis = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'StopBits'")[0]["PARAMETER_VALUE"]) == 0 ? StopBits.None : (Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'StopBits'")[0]["PARAMETER_VALUE"]) == 1 ? StopBits.One : StopBits.Two);
|
||||
Parity paritymsg = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'ParityMsg'")[0]["PARAMETER_VALUE"]) == 0 ? Parity.None : (Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'ParityMsg'")[0]["PARAMETER_VALUE"]) == 1 ? Parity.Odd : Parity.Even);
|
||||
int modbusPattern = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'ModbusPattern'")[0]["PARAMETER_VALUE"]);
|
||||
|
||||
string portname = ConfigurationManager.AppSettings["PortName"];
|
||||
int baudrate = int.Parse(ConfigurationManager.AppSettings["BaudRate"]);
|
||||
int databits = int.Parse(ConfigurationManager.AppSettings["DataBits"]);
|
||||
StopBits stopbis = (StopBits)int.Parse(ConfigurationManager.AppSettings["StopBits"]);
|
||||
Parity paritymsg = (Parity)int.Parse(ConfigurationManager.AppSettings["ParityMsg"]);
|
||||
int modbusPattern = int.Parse(ConfigurationManager.AppSettings["ModbusPattern"]);
|
||||
|
||||
//string portname = GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'PortName'")[0]["PARAMETER_VALUE"].ToString();
|
||||
//int baudrate = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'BaudRate'")[0]["PARAMETER_VALUE"]);
|
||||
//int databits = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'DataBits'")[0]["PARAMETER_VALUE"]);
|
||||
//StopBits stopbis = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'StopBits'")[0]["PARAMETER_VALUE"]) == 0 ? StopBits.None : (Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'StopBits'")[0]["PARAMETER_VALUE"]) == 1 ? StopBits.One : StopBits.Two);
|
||||
//Parity paritymsg = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'ParityMsg'")[0]["PARAMETER_VALUE"]) == 0 ? Parity.None : (Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'ParityMsg'")[0]["PARAMETER_VALUE"]) == 1 ? Parity.Odd : Parity.Even);
|
||||
//int modbusPattern = Convert.ToInt32(GlobalHelper.ParameterList.Select(" PARAMETER_CODE = 'ModbusPattern'")[0]["PARAMETER_VALUE"]);
|
||||
#if USE_LOCAL_TCP_DEBUG
|
||||
port = new System.Net.Sockets.TcpClient();
|
||||
|
||||
var adaptet = new NModbus.IO.TcpClientAdapter(port);
|
||||
#else
|
||||
port = new SerialPort(portname, baudrate, paritymsg, databits, stopbis);
|
||||
var adaptet = new NModbus.Serial.SerialPortAdapter(port);
|
||||
port = new SerialPort(portname, baudrate, paritymsg, databits, stopbis);
|
||||
var adaptet = new NModbus.Serial.SerialPortAdapter(port);
|
||||
adaptet.ReadTimeout = 200;
|
||||
#endif
|
||||
|
||||
var factory = new ModbusFactory();
|
||||
if (modbusPattern == 0)
|
||||
{
|
||||
var factory = new ModbusFactory();
|
||||
if (modbusPattern == 0)
|
||||
{
|
||||
|
||||
|
||||
master = factory.CreateRtuMaster(adaptet);
|
||||
}
|
||||
else
|
||||
{
|
||||
master = factory.CreateAsciiMaster(adaptet);
|
||||
}
|
||||
|
||||
master = factory.CreateRtuMaster(adaptet);
|
||||
}
|
||||
else
|
||||
{
|
||||
master = factory.CreateAsciiMaster(adaptet);
|
||||
}
|
||||
#if USE_LOCAL_TCP_DEBUG
|
||||
port.Connect("10.0.0.95", 5002);
|
||||
this._isConn = true;
|
||||
return true;
|
||||
#else
|
||||
|
||||
port.Open();
|
||||
port.Open();
|
||||
return port.IsOpen;
|
||||
|
||||
#endif
|
||||
|
||||
return true;
|
||||
#if RELEASE
|
||||
|
||||
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
@@ -136,7 +149,7 @@ namespace CleanMachineHMI
|
||||
isConn = false;
|
||||
return false;
|
||||
}
|
||||
#endif
|
||||
|
||||
}
|
||||
public void ClosePlcConn()
|
||||
{
|
||||
@@ -170,7 +183,7 @@ namespace CleanMachineHMI
|
||||
if (!string.IsNullOrEmpty(item.PlcItemDeviationAddress))
|
||||
{
|
||||
//string PlcItemId = item.PlcItemId.ToString();
|
||||
// string plcdatatype = item.PlcItemDataType.ToString();
|
||||
// string plcdatatype = item.PlcItemDataType.ToString();
|
||||
int plcItemDeviationAddress = Convert.ToInt32(item.PlcItemDeviationAddress);
|
||||
item.PlcItemValue = readBytArr_M[plcItemDeviationAddress].ToString();
|
||||
GlobalHelper.ShowSensorStatus(item, new EventArgs());
|
||||
@@ -216,7 +229,7 @@ namespace CleanMachineHMI
|
||||
{
|
||||
|
||||
string PlcItemId = item.PlcItemId.ToString();
|
||||
// string plcdatatype = item.PlcItemDataType.ToString();
|
||||
// string plcdatatype = item.PlcItemDataType.ToString();
|
||||
int plcItemDeviationAddress = Convert.ToInt32(item.PlcItemDeviationAddress);
|
||||
if (Convert.ToInt32(item.PlcItemPriAddress) < 409)
|
||||
{
|
||||
|
||||
Reference in New Issue
Block a user